3000 Series Fire Exit Hardware Selectior

FIRE EXIT HARDWARE

UL FIRE DOOR RATING

APPLICATION

MODEL NUMBER

MAXIMUM DOOR OPENING

(A) 3 HOUR

SINGLE DOORS

Rim type

7000-36

7000-48

4’0” X 8’0”

 

PAIRS OF DOORS

Two surface mounted standard vertical rod type or less bottom rod(LBR) application. Prefix BTL before Part#

a)   Swinging in same direction

b)  Swinging in opposite direction (double egress)

7100-3684

X

7100-3684

8’0” X 7’2”

 

7100-3696

X

7100-3696

7100-4896

X

7100-4896

8’0” X 8’0”

 

PAIRS OF DOORS

Two rim typr with mullion

7000-36

X

7000-48

8’0” X 8’0”

 ◎

 

All fire rated exit devices in all applications, are also labeled for (B) 11/2" hour, (C) 11/4" hour, (D) 1 hour, (E)3/4" hour.

All fire exit hardware meet UL10C and UBC 7-2-1997 codes.

HOW TO ORDER INFORMATION

Exit device model number

Panic grade

3000-36 Rim type 36” door

3000-48 Rim type 48” door

3100-3684 Vertical rod type 36” x 84”

3100-3696 Vertical rod type 36” x 96”

3100-4896 Vertical rod type 48” x96”

3100-36120 Vertical rod type 36” x 120”

3100-48120 Vertical rod type 48” x 120”

Fire grade

7000-36 Rim type 36” door

7000-48 Rim type 48” door

7100-3684 Vertical rod type 36” x 84”

7100-3696 Vertical rod type 36” x 96”

7100-4896 Vertical rod type 48” x 96”

 

1) Specify exit device model number according to size of door.

2) Specify trim selection. For interchangeable core prefix "IC" brfore part#. See page 3.

3) For vertical rod device pecify LHR (Left Hand Reverse) or RHR (Right Hand Reverse) for convenience easily field reverible, otherwise shipped as LHR.

4) Specify finish:

  Alim - Powder coated to match US26D.

  Duro - Powder coated to match US10B.

  Gold - Powder coated to match US4, US3.

5) On thru bolt applications, fire rated vertical rod device are packed with thru as standard feature. Thru bolts are also avai device. To order thru bolts add "SBN" to trim pack.

When ordering separately use following part#

part# 357─thru bolts for rim devices, 6PCs / pack.

part# 369─thru bolts for vertical rod devices, 14PCs / pack.

part# 363─thru bolts for rim devices, 6PCs / pack for 21/4" " thick doors.

part# 375─thru bolts for vertical rod devices, 14PCs / pack for 21/4" " thick doors.

Monday, 27 April 2015 13:57

3000 Series Strikes & Accessories

Strikes for use with 3100 vertical rod exit device

221

Standard for 3100. Applied to surface of floor or to a flat threshold. Standard packaging.

 C3 7 1

227

Applied to surface of stop. No mortise required. Standard packaging.

 C3 7 2

233

Bottom strike. Alternate bottom strike. Flush mounting stainless steel. Furnished with expansion shields. Requires mortise in the floor.

 C3 7 3

Strike for use with 3000 rim type exit device

239

For 3000 surface applied. Standard packaging.

 C3 7 4

Strikes for use with 7100 vertical rod fire rated exit device

245

Standard for 7100. Standard packaging.

C3 7 5

233

Bottom strike for 7100. Flush mounting stainless steel. Furnished with expansion shields.

Requires mortise in the floor. Standard packaging.

 C3 7 6

Strike for use with 7000 rim fire exit device

245

For 7000 surface applied. Standard packaging.

 C3 7 7

Overlapping Strike

251

Surface applied. Used on  inactive leaf for device on active keaf of pair of doors without mullion.

 C3 7 8

Additional Strikes

 LFF

Lock front filler.

 C3 7 9

SF

Strike filler.

C3 7 10


Accessories

Glass Bead Shim Kits

401 - For rim tyoe, 1/8" thick

406 - For vertical type, 1/8" thick

412 - For fire rated vertical type, 1/8" thick

When exit device are used with shim kits with outside trim, spindle length thumbpiece and thru bolt length must be increased accordingly.

 

Cylinder Dogging Kits

Prefix "CD" before part#. Available for all 3000 Series devices except fire exit hardware. Cylinder dogging with a mortise cylinder is located on the mounting insert lock bolt in retracted position. 27" minimum door width is required.

C3 7 11

Cyl dogging Kits Panic Rim & Vert Rod Device

C3 7 12

 

Monday, 27 April 2015 13:53

3000 Series Trim Selection

Lever Design  /  Knob Design  /  Escutcheon lever design  /  Thumbpiece Trim

LEON/MCKIN     Trim Selection

Lever Design

C3 6 1

Non handed Grade 1

Cylindrical body hardened steel heavy duty tailpiece.

For 1 3/4" " and 2 1/4" " doors. Available for fire and non fire rated rim and veritcal rod exit devices.

Rose diameter 3 1/2", lever length 4 3/4". Fits and covers 161 cutout.

Finishes: US26D, US10B, US3, US4.

 

8000/L Entrance

Key retracts latrchbolt, operates as classroom finctionunlocks lever.

ANSI Function - 08

 

CLU5000L  Cluth Free Wheeling(ENTRANCE)

Key operation latchbolt, unlocked lever.

ANSI Function - 08

 

8000/S Storeroom

Key operation lever, otherwise always locked. ANSI Function - 04

 

8000/P Passage

Lever always operable and free. ANSI Function - 15

 

8000/D Dummy

Dummy trim. One sided. ANSI Function - 10

 

Keyway:

Standard 6-pin “C” keyway. Also available in Schlage C-K, Russwin D1, Corbin 60, Sargent LA, Falcon/Weiser E, Assa, and Kaba high securitycylinders.


back to top

Knob Design

 C3 6 2

Non handed Grade 2

Cylindrical body hardened steel heavy duty tailpiece. For 13/4" doors. Available for fire and non fire rated rim and veritcal rod exit devices.

Rose diameter 3". Fits and covers 161 cutout.

Finishes: US26D

 

8000/K Entrance

Key retracts latrchbolt,  unlocks knob. ANSI Function - 08

 

8000/KP Passage

Knob always operable and free.  ANSI Function - 15

 

8000/KD  Dummy

Dummy trim. One sided.  ANSI Function - 10


back to top

Escutcheon lever design

 

C3 6 3

 

Construction

Grade 1, thrubolted design, clutch freewheeling. Non handed design. Easily field reversible.

Hardened ateel heavy duty tailpiece. Available for fire and non fire rated rim and vertical rod exit devices.

Finished

Power coated aluminum (alum)

Power coated dark bronze duranodic (duro)

Power coated glod

Door Thickness

Standard 13/4"

Escutcheon Dimensions

2 5/16" width x 8 1/2" " length. Lever length: 4 3/4". Fits and covers 2 1/8" 161 cutout.

 

ESC-00  Entrance

Key locks or unlocks thumbpiece. ANSI Fuction - 13 / 63

 

ESC-05  Storeroom

Key retracts latchbolt, otherwise always locked. ANSI Fuction - 04

 

ESC-30  Passage

Trim always operable and free. ANSI Fuction - 15 / 62

 

ESC-40  Dummy

Tummy trim. One sided. ANSI Fuction - 10

 

Keyway:

Standard 6-pin “C” keyway. Also available in Schlage C-K, Russwin D1, Corbin 60, Sargent LA, Falcon/Weiser E, Assa, and Kaba high security cylinders.

Interchangeable Core

Interchangable core locks will accept compatible 6 or 7 pin cores with BEST, FALCON and ARROW.


back to top

Thumbpiece Trim

 C3 6 5

C3 6 6

 

THP-00  Entrance

Key locks or unlocks thumbpiece. ANSI Function - 13 / 63

 

THP-05  Storeroom

Key retracts latchbolt, otherwise always locked. ANSI Function - 04

 

THP-30  Passage

Trim always operable and free. ANSI Function - 15 / 62

 

THP-40  Dummy

Tummy trim. One sided. ANSI Function - 10

 

Keyway:

Standard 6-pin “C” keyway. Also available in Schlage C-K, Russwin D1, Corbin 60, Sargent LA, Falcon/Weiser E, Assa, and Kaba high securitycylinders.

 

Interchangeable Core

Interchangable core locks will accept compatible 6 or 7 pin cores with BEST, FALCON and ARROW.

 

Finished

Power coated aluminum (alum), dark bronze duranodic (duro), glod.

 

Door Thickness

Standard 1 3/4"

Monday, 27 April 2015 13:47

#ALM 3000-36 & #ALM 7000-36

LEON/MCKIN     Alarm Exit Hardware

#ALM 3000-36 / #ALM 7000-36

 C3 5 1

C3 5 2

 

Rim Type Exit Devices

ALM 3000-36 Alarm rim type 36"door (panic grade)

ALM 3000-48 Alarm rim type 48"door (panic grade)

ALM 7000-36 Alarm rim type 36"door (fire grade)

ALM 7000-48 Alarm rim type 48"door (fire grade)

 

Vertical Rod Type Exit Devices

Prefix "ALM" before part #.

 

Dimensions

Alarm units has an internal horn. When the push rail is depressed, the horn sounds to provide audible an means of signaling that the door has been opened and violated,

The unit has changeable 2 minute alarm cutoff or manual reset. Preset at factory for 2 minute alarm cut off.
Jumper cable is provided to swich to continuous alarm.

The key switch to turn the alarm off is a standard 11/4"cylinder with "C" keyway. The alarm operates on one standard 9 volt transistor battery. when battery is weak the horn will emit an intermittent signal.

Alarmed units are supplied with two switches. One switch moniters the push rail and the other switch monitors the latchbolt for full proof security.
Unit includes "emergency exit only. Alarm will sound"

 

Monday, 27 April 2015 13:44

#3100BTL & #7100BTL

LEON/MCKIN     #3100-BTL & #7100-BTL Vertical Rod Type Exit Device Less Bottom Rod - LBR

 C3 4 1

C3 4 2

Specifications

LBR----------------------- No Bottom Strike, Free access for wheel chairs, strectcher and carts therefore eliminates tripping potential and disfiguration of floors due to dragging of bootom bolts.
For Doors --------------- 13/4” thick standard. 3 3/4” ” minimum stile width required for signle door application. 3 1/2” minimum stile width required for double door application. Lever trims available.
Chassis ------------------ Nonferrous alloy (Panic Grade), steel (Fire Grade).
Cover------------ Nonferrous alloy. Cover stock hollow metal doors with 161 cutout.
Mounting ---------------- Furnished standard with wood and machine screws. Thru bolts are standard packaging on fire rated devices.
Hand --------------------- Easily field reversible. Specify at time of order LHRB, RHRB for convenience.
Dogging Feature ------ Allen-type key furnished standard on non-fire labeled devices.
UL and ULC Listed ---- All Series for panic. BTL Series for fire exit hardware for all types of 8’ x 8’ double doors including double egress for up to 3 hours metal. Conforms to standards UL 10C and UBC 7-2-1997 codes.
Finish -------------------- Aluminum (alum), dark bronze duranodic (duro), gold.
Door size --------------- 36” x 84” / 48” x 96” / 36” x 96” doors.
Alarm -------------------- Available. Prefix “Alrm” before part #.
End Cap------------------Steel construction.
Latch Bolt,Spring ----- Stainless steel.
ANSI standard --------- A156.3, Grade 1.
Rail Assembly----- Heavy gauge steel, painted.
Strike --------------------- see strike page.

Dimensions
Touchbar height to finished floor 41"(1043mm) at center
Touchbar projection
               neutral

1/2"(64mm)
Center case 1/8x2 3/4X 2(129mm x 69mm x 52mm)

Device length - Short 3'(914mm)
                        Long 4'(1219mm)

2'9"x3'(840mm to 914mm) door size
2'9"x4'(1145mm to 1219mm) door size
Panic grade top & bottom latch case 315/16"x21/8"x13/8"(100mm x 52mm x 42mm)
Fire grade top latch case 315/16"x211/16"x13/16"(100mm x 68mm x 53mm)
top and bottom rod length for 36" x 84" doors Top rod 43 1/4" (1350mm)
top and bottom rod length for 48" x 96" doors Top rod 53 1/16" (1350mm)
Vertical rods 1/2"(13mm) Round tubing.

 

C3 3 3

 

Monday, 27 April 2015 12:24

#3100 & #7100

LEON/MCKIN     #3100 & #7100 Vertical Rod Type Exit Device

 C3 3 1

Specifications

For Doors -------------- 13/4” thick standard optional 21/4” minimum stile width required for signle or double door application using standard 239 strike and pull or lever trims.
Chassis ------------------ Nonferrous alloy (Panic Grade), steel (Fire Grade).
Cover------------ Nonferrous alloy. Cover stock hollow metal doors with 161 cutout.
Mounting ---------------- Furnished standard with wood and machine screws. Available with thru bolts on request.
End Cap-------Steel construction.
Alarm--------- Available. Prefix “Alrm” before part #.
End Cap-------Steel construction.
Hand --------------------- Easily field reversible. Specify at time of order LHRB, RHRB for convenience.
UL and ULC Listed -- 3100 Series for panic. 7100 Series for fire exit hardware for all types of 8’ x 8’ double doors for up to 3 hours fire labeled installations, conforms to standards UL 10C and UBC 7-2-1997 codes.
Dogging Feature ------ Allen-type key furnished standard on non-fire labeled devices.
Finish -------------------- Aluminum (alum), dark bronze duranodic (duro), gold.
Rail Assembly----- Heavy gauge steel, painted.
Latch Bolt,Spring ----- Stainless steel.
ANSI standard --------- A156.3, Grade 1.
Rail Assembly----- Heavy gauge steel, painted.
Strike --------------------- see strike page.
Door size--------------- 36” x 84” / 48” x 96” / 36” x 96” doors.

  

Dimensions
Touchbar height to finished floor 41"(1043mm) at center
Touchbar projection
               neutral
               depressed

1/2"(64mm)
3/4"(45mm)
Center case 1/8x2 3/4X 2(129mm x 69mm x 52mm)

Device length - Short 3'(914mm)
                        Long 4'(1219mm)

2'9"x3'(840mm to 914mm) door size
2'9"x4'(1145mm to 1219mm) door size
Panic grade top & bottom latch case 315/16"x21/8"x13/8"(100mm x 52mm x 42mm)
Fire grade top latch case 315/16"x211/16"x13/16"(100mm x 68mm x 53mm)
Fire grade bottom latch case 315/16"x21/8"x13/8"(100mm x 52mm x 42mm)
top and bottom rod length for 36" x 84" doors Top rod 43 1/4" (1350mm), bottom rod 37 3/4" (960mm)
top and bottom rod length for 48" x 96" doors Top rod 53 1/16" (1350mm), bottom rod 37 3/4" (960mm)
Vertical rods 1/2"(13mm) Round tubing.

 

C3 3 2

C3 3 3

Monday, 27 April 2015 08:35

#3000 & #7000

LEON/MCKIN     #3000 & #7000 Rim Type and Fire Exit Device

 C3 2 1

Specifications

For Doors

13/4" thick standard optional 21/4thick. 41/2" minimum stile width required for signle or double door application using standard 239 strike and pull or lever trims.

Chassis

Nonferrous alloy (Panic Grade), steel (Fire Grade).

Cover

Nonferrous alloy. Cover stock hollow metal doors with 161 cutout.

Mounting

Furnished standard with wood and machine screws. Available with thru bolts on request.

End Cap

Steel construction.

Alarm

Available. See page.

Hand

Non handed, center hub.

Latch Bolt

Stainless steel 3/4" throw.

Spring

Stainless steel throughout.

ANSI standard

A156.3, Grade 1.

Rail Assembly

Heavy gauge steel, painted.

Strike

239 packed atandard (see strike page).

Dogging Feature

Allen-type key furnished standard on non-fire labeled devices. Cylinder dogging available.

Mullion

Available.

UL and ULC Listed

3000 Series for panic. 7000 Series for fire exit hardware for all types of 4' x 8' single doors and 8' x8' doors for up to 3 hours fire labeled installations, conforms to standards UL 10C and UBC 7-2-1997 codes.

Finish

Alum/Duro/Gold

Door size

32" / 36" / 48"

  

 

Dimensions

Touchbar height to finished floor

41"(1043mm) at center

Touchbar projection
                 neutral
                 depressed

2 1/2"(64mm)
1 3/4"(45mm)

Center case

5 1/8x2 3/4 x2(129mm x 69mm x 52mm)

Device length - Short 3'(914mm)
             Long 4'(1219mm)

2'9"x3'(840mm to 914mm) door size
2'9"x4'(1145mm to 1219mm) door size

 

C3 2 2

Wednesday, 22 April 2015 15:00

5000 / 8000 Series

LEON/MCKIN

5000 & 8000 Rim Type and Fire Exit Device

5000 & 8000 Rim Type and Fire Exit Device

Now upgraded to ANSI A156.3, Grade 1

 C10 1

Features & Construction

  • ANSI A156.3, Grade 1 heavy duty exit device in surface vertical rod and rim designs.
  • UL Listed for Panic and UL 10C, UBC 7-2-1997 codes.
  • UL Listed for Fire Exit Hardware. 3 hours.
  • Conforms & Meets ADA Regulations.
  • (A) label rating on pairs of doors up to 8’0” x 8’0” swinging in same or opposite directions.
  • Uncompromising security and safety in single and double fire exit doors.
  • Chassis mounted unit construction.
  • Available in many different functions. Lever and escutcheon tirms are grade 1 construction with clutch freewheeling mechanism. Rose and escutcheon covers 161 cut out.

 

Suggested Architect’s Specifications

  • All exit devices shall be of touch bar design with smooth operation and be operative over 2/3 of the door’s clear opening width.
  • All exit devices must be listed under “Panic Hardware” in the Accident Equipment List of Underwriter’s Laboratories, Inc. Where labeled doors are used as exits, they must be equipped with labeled Fire Exit Hardware and UL 10C, UBC 7-2-1997 codes.
  • All exit devices shall be of chassis mounted unit construction.
Wednesday, 22 April 2015 06:54

MR7700/7586F/7587F

FC-MR7700 Series Exit Devices

Grade (1) Mortise Exit Device

 C8 1

  

Specifications

For Doors Wood / metal. 1 3/4” (44.5mm) minimum thickness;
4 1/2” (114mm) minimum stile width
Chassis Nonferrous alloy
Chassis Cover Bronze or stainless steel
End Cap Brass, bronze or stainless Steel Construction
Handing Non-Handed. Specify RHR or LHR for convenience
ANSI standard A156.3, Grade 1.
Mounting Furnished standard with wood and machine screws.
Strike Standard ANSI strike
Mortise Lock Grade (1) for 1 3/4” (44.5mm) thick doors. Reversible. Fits door prepared for ANSI Standard A115.1
Fire Exit hardware MR7700 Series for fire exir hardware for all types of 8” x 8” double doors for up to 3 codes.
Trim See trim Designs section
Finish (ELR) Electrical Latch Retraction and RX & LX Signal Switch available
Door size MR7700-36 for 36” doors.
MR7700-48 for 48” doors.

 

C8 2  


 

MR7700 Mortise Lock Rim Exit Devices

Trim Selection

ESCUTCHENON LEVER DESIGN

 C5 3

Construction

- Rigid, non clutch mechanism.

- Double heavy duty spring support to prevent sagging and enhance openration.

- Grade 1, thrubolted design, clutch freewheeling. Non handed design. Easily field reversible.

- Hardened ateel heavy duty tailpiece. Available for fire and non fire rated rim and vertical rod exit devices.

 

Door Thickness

Standard 1 3/4"

 

Escutcheon Dimensions

2" width x 8 " length. Lever length:4 3/4"

Fits and covers 2 1/8" 161 cutout

 

MRESC-7700     Entrance

key locks or unlocks lever ANSI Fuction - 63

 

MRESC-7705     Storeroom
key retracts latchbolt, otherwise always locked. ANSI Fuction - 04

 

MRESC-7730     Passage

Trim always operable and free. ANSI Fuction - 62

 

Keyway:

Standard 6-pin “C” keyway. Also available in Schlage C-K, Russwin D1, Corbin 60, Sargent LA, Falcon/Weiser E, Arrow, Yale GA, Yale 8, Kwikset. Can also accept Medeco,  Assa, and Kaba high security cylinders.

Metal Doors / Wood Doors / Trim Selection


FC-7586F (MCVR7700) For Metal Doors

FC-7587F (WCVR7700) For Wood Doors

Grade 1 Concealed Vertical Rod Exit Device 

 C9 1

C9 2

 

 

Specifications

For Doors Wood / metal. 1 3/4” (44.5mm) minimum thickness;
1/2” (114mm) minimum stile width
Chassis Nonferrous alloy
Chassis Cover Zinc
End Cap Zinc Construction
Handing Non-Handed. Specify RHR or LHR for convenience
ANSI standard A156.3, Grade 1.
Mounting Furnished standard with wood and machine screws.
Strike Standard ANSI strike
Mortise Lock Grade (1) for 1 3/4” (44.5mm) thick doors. Reversible.
Fits door prepared for ANSI Standard A115.1
Fire Exit hardware MR7700 Series for fire exir hardware for all types of 8” x 8” double doors for up to 3 codes.
Trim See trim Designs section
Door size FC7586F/7587F-3684 for 36" x 84" doors.
FC7586F/7587F-3696 for 36" x 96" doors.
Other sizes available on request

 

C9 3


 

FC-7586F(MCVR7700) / FC-7587F(WCVR7700)

Concealed Vertical Rod Exit Device for Wood & Metal Doors

Trim Selection

C9 6

ESCUTCHON LEVER DESIGN

Construction

- Grade 1, thrubolted design, clutch freewheeling. Non handed design. Easily field reversible.

- Hardened ateel heavy duty tailpiece. Available for fire and non fire rated rim and vertical rod exit devices.

 

Finishes

Architectueal plated finishes

 

Door Thickness

Standard 1 3/4"

 

Escutcheon Dimensions

2 5/16" width x 8 1/2" length. Lever length: 4 3/4". Fits and covers 2 1/8" 161 cutout

 

CVRESC-7700      Entrance

Clutch Mechanism key locks or unlocks lever Operates as classroom function ANSI Fuction - 63

 

CVRESC-7705      Storeroom

Clutch Mechanism key retracts latchbolt, otherwise always locked. ANSI Fuction - 04

 

CVRESC-7730      Passage

Trim always operable and free. ANSI Fuction - 62

 

CVRESC-7740      Dummy

Dummy trim. One sided. ANSI Fuction - 10

 

Keyway:

Standard 6-pin “C” keyway. Also available in Schlage C-K, Russwin D1, Corbin 60, Sargent LA, Falcon/Weiser E, Arrow, Yale GA, Yale 8, Kwikset. Can also accept Medeco,  Assa, and Kaba high security cylinders.

 

Interchangeable Core:

Interchangeable core locks will accept compatible 6 or 7 pin cores with BEST, FALCON and ARROW.

Wednesday, 22 April 2015 06:54

1000 / 4000 Series

1000/4000 (9900 & F9900) Panic & Fire Rim Type Exit Devices

1100/4100 (9960 & F9960) Vertical Rod Panic & Fire Exit Devices

ANSI A156.3, Grade 1

 C7 1

Features & Construction

  • For use in institutions, schools, universities, commercial buildings where heavy duty reliable operation is a reqirement.
  • ANSI A156.3, Grade 1 heavy duty exit device in surface vertical rod and rim designs.
  • Rail assemblies are heavy duty extruded aluminum body with stainless steel push pad and end caps are made of brass, bronze or stainless steel. Rail travels in direction of the door swing.
  • Trims are thru bolted for additional security.
  • Conforms & Meets ADA Regulations.
  • UL Listed for Panic and UL 10C, UBC 7-2-1997 codes.
  • UL Listed for Fire Exit Hardware. 3 hours.
  • (A) label rating on pairs of doors up to 8’0” x 8’0” swinging in same or opposite directions.
  • Uncompromising security and safety in single and double fire exit doors.
  • Chassis mounted unit construction.
  • Available in many different functions. Lever and escutcheon tirms are grade 1 construction with clutch freewheeling mechanism. Rose and escutcheon covers 161 cut out.

 

Suggested Architect’s Specifications

  • All exit devices shall be of touch bar design with smooth operation and be operative over 2/3 of the door’s clear opening width.
  • All exit devices must be listed under “Panic Hardware” in the Accident Equipment List of Underwriter’s Laboratories, Inc. Where labeled doors are used as exits, they must be equipped with labeled Fire Exit Hardware and UL 10C, UBC 7-2-1997 codes.
  • All springs shall be of stainless steel throughout.
  • All exit devices shall be of chassis mounted unit construction.
  • All exit device shall be ANSI A156.3, Grade 1.
Page 4 of 5